2N Redundancy
2NA redundancy model in which every system component is fully duplicated, allowing one complete half to fail with no impact on the load.
physicalA large-scale GPU cluster purpose-built for AI model training and inference, requiring specialised high-density power, liquid cooling, and high-speed network fabric infrastructure.
ai-infrastructurePhysical barriers preventing hot exhaust and cold supply air from mixing in a data hall.
CoolingASHRAE TC9.9 defines classes A1–A5 and B/H for allowable IT equipment inlet air temperatures, guiding data centre cooling design.
CoolingSpare energy capacity available for additional IT workloads, expressed over a measurement period.
SustainabilitySpare power capacity available for additional IT load: the headroom between current IT draw and the rated IT load.
SustainabilityThe average temperature of waste heat leaving the data centre: determines suitability for heat recovery applications.
SustainabilityEnergy produced by backup generators during the measurement period: tests, mains outages or peak-shaving.
SustainabilityA physical server provisioned directly to a single workload without a virtualisation layer, delivering maximum compute performance and predictable latency at the cost of reduced density and flexibility.
virtualisationLarge-scale battery installations that store electrical energy for grid balancing, peak shaving or backup power, increasingly used alongside or instead of diesel generators.
Power EfficiencyA filler panel installed in unused rack unit spaces to prevent hot exhaust air from recirculating to the front of the rack.
physicalCentral control system for a building's mechanical and electrical services including HVAC, power, and access control.
Management SystemsThe process of tracking, forecasting and planning available power, cooling, space and network resources in a data centre to meet future demand.
managementAnnual CO₂ equivalent emissions from data centre energy divided by IT equipment energy in kWh.
SustainabilityA refrigeration machine that produces chilled water for distribution to CRAH units or CDUs in a data centre cooling system.
CoolingService model where customers own their servers but rent space, power, and connectivity from a facility operator.
Service ModelsStandalone precision cooling unit with an internal compressor used to cool server halls.
CoolingFan-coil unit that uses chilled water from a central plant to cool data hall air. More efficient than CRAC at scale.
CoolingA centralised repository of information about IT infrastructure components and their relationships, used to support change and incident management.
managementA facility unit that conditions and distributes liquid coolant to direct-liquid-cooled server racks, managing flow rate, supply temperature, and pressure between the facility chilled water loop and rack manifolds.
CoolingHow efficiently the cooling system removes heat from the IT space relative to the cooling energy it consumes. Higher is better.
SustainabilityTotal energy used by all cooling systems: CRAHs, CDUs, chillers, cooling towers, pumps and fans.
SustainabilityCooling energy as a share of IT energy — kWh of cooling per kWh of IT load.
SustainabilityA heat rejection device that transfers waste heat from the condenser water loop to the atmosphere through evaporation.
CoolingNVIDIA's parallel computing platform and programming model that enables GPUs to be used for general-purpose computation, including AI and machine learning.
ai-infrastructureInverse of PUE as a percentage. DCiE = (IT Power ÷ Total Power) × 100. Higher is better.
Power EfficiencySoftware platform that monitors, measures, manages, and controls all data centre infrastructure and IT assets.
Management SystemsA programmable processor that offloads networking, storage and security functions from the CPU, freeing it for application workloads.
ai-infrastructureTotal energy consumed by the data centre across all systems: IT, cooling, power distribution, lighting and ancillaries.
SustainabilityThe temperature difference between the supply and return of a cooling circuit; a key indicator of how efficiently heat is being transferred.
CoolingA rotary UPS that integrates a flywheel, diesel engine and generator into a single unit, eliminating static battery banks.
Power EfficiencyCooling method bringing liquid directly to heat-generating components, enabling high-density rack deployments.
CoolingElectricity used to raise waste heat to a usable temperature via heat pumps, enabling heat recovery from low-grade sources.
SustainabilityThe European standard series for data centre facilities, covering power, cooling, physical security and management systems with a class rating system from 1 to 4.
managementFactory Acceptance Test and Site Acceptance Test — the two commissioning milestones at which equipment is formally verified before handover.
physicalA network topology used in high-performance data centres that provides full bisection bandwidth by over-provisioning links at higher layers of the hierarchy.
NetworkingMeasure of processor computational throughput, used to compare GPU and HPC system performance.
Compute MetricsUsing outside ambient air or water temperature to cool a facility without mechanical refrigeration, reducing energy use.
CoolingNVIDIA's Blackwell-generation rack-scale AI system — 36 Grace CPUs and 72 Blackwell GPUs interconnected at 130 TB/s via NVLink — delivering 1.4 exaFLOPS of AI performance at roughly 120 kW per rack.
ai-infrastructureEU Regulation 2016/679 requiring appropriate technical and organisational safeguards for personal data, with direct implications for data residency and datacenter location decisions.
Management SystemsA massively parallel processor originally designed for graphics rendering, now the primary compute engine for AI training and inference at scale.
ai-infrastructureThe share of a data centre energy that comes from green sources, based on onsite generation and the grid renewable ratio.
SustainabilityThe portion of grid energy drawn by the data centre attributable to renewable generation in the local grid mix.
SustainabilityThe renewable percentage of the local electricity grid: proportion of grid electricity from renewable sources in the relevant market.
SustainabilityA 3D-stacked DRAM standard co-packaged on the GPU die, delivering memory bandwidths of 3–5 TB/s to feed the parallel compute engines of modern AI accelerators.
ai-infrastructureRack arrangement separating hot exhaust air from cold supply air to improve cooling efficiency.
CoolingVery large data centre (typically 40+ MW) operated by cloud providers at massive scale with highly standardised infrastructure.
Facility TypesSoftware or firmware that creates and manages virtual machines by abstracting physical hardware resources and arbitrating access between guest operating systems and the underlying CPU, memory, and I/O.
virtualisationA cooling method in which servers are fully submerged in a dielectric fluid that absorbs heat directly from components.
CoolingA high-speed, low-latency network fabric used in AI supercomputer clusters to connect GPUs across nodes, enabling RDMA at speeds up to 400 Gb/s per port.
ai-infrastructureAn out-of-band server management standard that allows remote power control, hardware sensor monitoring, and console access independent of the host operating system via a dedicated Baseboard Management Controller (BMC).
managementThe international standard for Business Continuity Management Systems (BCMS), defining how organisations plan, test, and maintain recovery capability for disruptive incidents.
Management SystemsThe international standard for Energy Management Systems, requiring organisations to systematically improve energy performance through policy, objectives and monitoring.
managementThe international standard specifying requirements for an Information Security Management System (ISMS), widely required by enterprise colocation and cloud customers as a condition of contract.
Management SystemsEnergy used by IT equipment: servers, storage and networking within the data centre.
SustainabilityThe average temperature of air entering IT equipment: a key parameter for cooling setpoint management and ASHRAE class compliance.
SustainabilityA formal process for assessing, approving and controlling changes to critical infrastructure to prevent unintended outages.
managementSpecialist contractor responsible for integrating all building and IT systems into a single unified management platform.
Management SystemsMechanical, Electrical and Plumbing — the three engineering disciplines that cover a data centre's physical infrastructure.
physicalAn open serial and TCP/IP protocol connecting industrial devices — BMS controllers, CDUs, chillers, generators — enabling register-level read/write of sensor data and control parameters.
managementMean Time Between Failures and Mean Time To Repair — the two fundamental reliability metrics for data centre equipment and systems.
managementAn NVIDIA GPU feature that partitions a single physical GPU into up to seven isolated instances, each with dedicated compute, memory and bandwidth resources.
ai-infrastructureDesign model where N systems are needed for full operation and one additional unit provides backup if any N fails.
Physical InfrastructureA file-level storage system connected to a network that allows multiple clients to access shared file systems over NFS or SMB/CIFS — commonly used for shared datasets, home directories, and AI training data staging.
storageNon-industrial water recovered and reused on site: rainwater harvesting or grey water used in cooling systems.
SustainabilityNVIDIA's proprietary high-bandwidth interconnect for GPU-to-GPU and GPU-to-CPU communication within a server or rack-scale system.
ai-infrastructureA host controller interface optimised for NAND flash SSDs, providing sub-100 µs latency and over 7 GB/s sequential throughput over PCIe — the performance storage standard for servers, distinct from NVMe-oF which extends the protocol over network fabrics.
storageA protocol extension that allows NVMe storage commands to be carried over a network fabric (InfiniBand, RoCE or Fibre Channel), providing remote storage with near-local latency.
ai-infrastructureDevice that distributes electrical power from a single high-amperage source to multiple rack-mounted devices.
Power InfrastructureThe ratio of real power (kW) to apparent power (kVA); a measure of how efficiently a load draws current.
Power EfficiencyA long-term contract between a power generator and a buyer that fixes the price and volume of electricity, typically used to secure renewable energy supply.
Power EfficiencyThe complete path from the grid connection through to the IT equipment, including transformers, switchgear, UPS, generators, busbars and PDUs.
Power EfficiencyRatio of total facility power to IT equipment power. PUE 1.0 is perfect; the industry average is ~1.5.
Power EfficiencyStandard unit of vertical height for rack-mounted equipment. 1U = 44.45 mm (1.75 in).
Physical InfrastructureThe design capacity for IT power: the maximum IT load the facility infrastructure is engineered to support.
SustainabilityA network protocol that enables RDMA (remote direct memory access) over standard Ethernet, used in AI clusters as an alternative to InfiniBand.
ai-infrastructureMaximum acceptable age of data recoverable after a disruption — how much data loss is tolerable.
Business ContinuityMaximum acceptable time to restore a service or system after a disruption.
Business ContinuityA method of data transfer that allows one computer to directly access the memory of another without involving either machine's CPU or OS, enabling very low latency communication.
ai-infrastructureMarket-based instruments that certify that one megawatt-hour of electricity was generated from a renewable source, used by organisations to support renewable energy claims.
managementThe site own renewable share: total renewable energy divided by DC energy consumption, multiplied by 100.
SustainabilityRenewable energy attributed through Guarantees of Origin certificates or equivalent instruments such as RECs.
SustainabilityRenewable energy generated on the data centre site: typically solar PV, small-scale wind or biogas CHP.
SustainabilityRenewable energy secured through Power Purchase Agreements: contracted volumes of renewable generation attributed to the site.
SustainabilityThe GHG Protocol's three categories of greenhouse gas emissions: direct (Scope 1), indirect from purchased energy (Scope 2), and value chain (Scope 3).
managementContractual commitment defining minimum acceptable uptime, response times, and service quality a provider must deliver.
Contracts & AvailabilityThe dominant protocol for monitoring and managing networked devices — switches, PDUs, UPS systems — by polling OID values from MIBs or receiving asynchronous trap alerts.
managementA US auditing standard for service organisations covering security, availability, processing integrity, confidentiality and privacy controls over a defined period.
managementA two-tier network topology in which every leaf switch connects to every spine switch, providing predictable low-latency east-west traffic paths — the dominant architecture for modern datacentre fabrics.
NetworkingAn electronic switch that transfers a critical load between two independent power sources in under 4 milliseconds.
Power EfficiencyA dedicated high-speed network providing block-level storage access between servers and storage arrays, appearing to servers as locally attached disks — used for databases, virtualised workloads, and mission-critical applications.
storageA US telecommunications standard for data centre infrastructure, defining four rated levels (Rated 1–4) for power, cooling, cabling and architecture.
managementNetwork switch at the top of a server rack that aggregates all server connections within that rack.
NetworkingFull lifecycle cost of owning and operating IT infrastructure including capex, opex, cooling, space, and labour.
FinancialDrinking-quality water supplied to the site, used primarily in cooling towers, adiabatic coolers and humidification.
SustainabilityThe sum of all renewable energy attributed to the data centre: onsite generation, PPAs and Guarantees of Origin.
SustainabilityTotal water consumed by the data centre across all sources: potable, non-potable and reused water combined.
SustainabilityBattery-backed power system that maintains continuous supply to critical loads during mains failure.
Power InfrastructureFour-level system rating data centre design resilience from basic (Tier I) to fault-tolerant (Tier IV).
Standards & ClassificationsNVIDIA's GPU architecture after Blackwell, planned for 2026, targeting a further ~4× increase in AI compute per chip and continuing the biennial architecture cadence.
ai-infrastructureA logical partition of a physical network that segments traffic into independent broadcast domains, used in datacentres to isolate management, storage, production, and customer traffic on shared switching infrastructure.
NetworkingA software emulation of a physical computer that runs a complete operating system and applications in isolation from other VMs sharing the same physical host, managed by a hypervisor.
virtualisationA liquid cooling approach that uses elevated water temperatures (30–50°C) at the CDU or cold plate, enabling free cooling for more of the year.
CoolingTotal waste heat rejected by the data centre: DC energy consumption minus any heat usefully reused.
SustainabilityWaste heat recovered from the data centre and delivered to productive use outside the boundary: district heating, domestic hot water, etc.
SustainabilityAnnual site water usage (litres) divided by IT equipment energy (kWh). Lower is better.