POD Liquid
Monitoring
Real-time liquid cooling intelligence for high-density data centres. Monitor every CDU, every circuit, every drop — from a single pane of glass.

Thousands
Monitoring Points
Per deployment
<1s
Alert Latency
Real-time response
24/7
Managed Service
Break-fix SLA
100%
Open Protocol
Modbus / BACnet
The Challenge
High-density GPU deployments demand liquid cooling — but tenants don't want to monitor or maintain secondary loop pipework. Landlords need a managed, independent solution that provides full visibility without adding operational burden.
Thermal Complexity
CDUs with dual plate exchangers, variable-speed pumps, primary and secondary circuits — each with unique temperature, pressure, and flow characteristics.
Demarcation Ambiguity
Where does landlord responsibility end and tenant responsibility begin? The CDU is the interface — half belongs to each party. Clear monitoring boundaries are essential.
Resilience & SLA
N+2 pump configurations, automatic failover on anomaly detection, and contractual SLAs that span both landlord and tenant — all require intelligent monitoring.
Immersive Data Hall View
Navigate your entire cooling infrastructure in a fully interactive 3D environment. Heat-mapped racks, colour-coded CDUs, and click-to-inspect telemetry — purpose-built for liquid cooling operators.

Complete Circuit Visibility
Every Coolant Distribution Unit monitored in real time — primary building water circuit and secondary rack coolant circuit, with full sensor telemetry at your fingertips.
Primary Circuit (Building Water)
Secondary Circuit (Rack Coolant)
CDU Internals

Platform Capabilities
Designed for the specific demands of liquid-cooled data centre environments.
Real-Time Monitoring
Temperature, pressure, flow rate, and humidity across thousands of monitoring points. Sub-second data refresh with configurable polling intervals.
Intelligent Alerting
Threshold-based and anomaly-detected alarms. Automated ticket generation with severity classification — critical, warning, and informational.
Leak Detection
Per-rack leak detection probes with automatic isolation — water valves close and shunt trips kill power to prevent chip overheating. Panel turns red on detection.
Pump Failover Logic
N+2 pump resilience monitoring. Automatic detection of out-of-range states (pressure, flow, temperature) with failover to secondary pump — zero downtime.
Power & PUE Analytics
Track total power, IT load, cooling load, and PUE across facilities. Time-series trending with per-facility and per-rack breakdowns.
Secure & Open Protocol
Modbus and BACnet integration via marshalling box. Standalone or BMS-integrated deployment. Secure bridging with full accreditation.
Asset Management
Full inventory of CDUs, racks, sensors, valves, and pipework. Serial numbers, positions, maintenance history, and warranty tracking.
Multi-Site Portfolio
Manage London, Paris, and beyond from one platform. Regional views with facility-level drill-down and cross-site comparison.
Managed Break-Fix
SLA-backed on-site engineering response. Automated dispatch, issue tracking, and resolution reporting — the tenant never has to touch the secondary loop.

Power & Efficiency at a Glance
Track total power consumption, IT load vs cooling load, and PUE in real time. Identify inefficiencies across facilities and optimise cooling energy spend.
- Total power, IT load, and cooling load breakdown
- PUE tracking with trend analysis
- Per-facility power distribution
- Tap-off telemetry and bus-bar monitoring
- 24-hour, 7-day, and 30-day time-series views
System Architecture
POD Liquid Monitoring sits at the demarcation point between landlord and tenant infrastructure, providing independent visibility without requiring BMS access.
Plant Side
Chilled water supply
DPH
Distribution pump header
CDU
Demarcation point
Secondary Loop
Rack coolant circuit
RDX / DTC
Direct to chip cooling
Standalone Deployment
Operates independently with its own sensor network and control logic. Break-fix engineers access a dedicated portal — no BMS credentials required.
BMS Integration
Connects via Modbus marshalling box to appear as a subsystem on the main BMS. Full data mirroring or critical-alarm-only — configurable per client.
Proactive, Not Reactive
Every alert is classified, tracked, and routed to the right team. From high-temperature warnings to leak detection events — automated ticketing ensures nothing is missed.
Leak detected — rack isolated, shunt trip activated
CDU pressure approaching capacity threshold
Scheduled pump rotation completed successfully

Built For
Colocation Providers
Offer liquid cooling monitoring as a managed service to tenants. Clear demarcation, independent operation, and SLA-backed response.
Hyperscale Operators
Scale from hundreds to thousands of monitoring points across multiple halls and sites. GPU pods, CDUs, buffer tanks — all in one view.
Mechanical Contractors
Commission, maintain, and service liquid cooling infrastructure with full visibility. Asset tracking, maintenance scheduling, and break-fix dispatch.
Ready to See It in Action?
Schedule a live demonstration of POD Liquid Monitoring with your facility data. We'll show you exactly how it maps to your CDU fleet, sensor network, and operational workflow.